Difference between revisions of "VTube-LASER v2.9.10"
(→25pxNEW LASER SCAN FILTER - MINIMUM NUMBER OF POINTS REQUIRED IN LASER STRIPES) |
(→25pxNEW LASER SCAN FILTER - MINIMUM NUMBER OF POINTS REQUIRED IN LASER STRIPES) |
||
Line 33: | Line 33: | ||
Previous versions of VTube-LASER had no minimum point count per laser stripe. However, it helps to remove any LASER stripe that doesn't have enough data - because that often signals outlier points.<br><br> | Previous versions of VTube-LASER had no minimum point count per laser stripe. However, it helps to remove any LASER stripe that doesn't have enough data - because that often signals outlier points.<br><br> | ||
− | + | You can experiment with larger numbers to have a greater culling effect if you experience lone outliers.<br><br> | |
The new value can be entered and adjusted in the MEASURE SETUP / LASER tab menu.<br><br> | The new value can be entered and adjusted in the MEASURE SETUP / LASER tab menu.<br><br> | ||
− | [[image:vtl_v2.9.10_minimum_number_of_points_per_stripe_closeup.png]] | + | [[image:vtl_v2.9.10_minimum_number_of_points_per_stripe_closeup.png]]<br><br> |
+ | |||
+ | The default minimum is now 5 points per stripe.<br><br> | ||
+ | |||
+ | [[image:laser stripe with 5 vertices minimum.png|300px]] | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image:vtl_v2.9.10_minimum_number_of_points_per_stripe | + | [[image:vtl_v2.9.10_minimum_number_of_points_per_stripe.png|300px]] |
</td> | </td> | ||
Revision as of 17:22, 5 July 2018
Revision 2.9.10Release Date: July 4, 2018
|
NEW LASER SCAN FILTER - MINIMUM NUMBER OF POINTS REQUIRED IN LASER STRIPES
Previous versions of VTube-LASER had no minimum point count per laser stripe. However, it helps to remove any LASER stripe that doesn't have enough data - because that often signals outlier points. You can experiment with larger numbers to have a greater culling effect if you experience lone outliers. The new value can be entered and adjusted in the MEASURE SETUP / LASER tab menu. The default minimum is now 5 points per stripe. |
NEW - LASER SCAN FILTER SOUND
In previous versions of VTube-LASER, the scanning sound goes silent if the SCAN BUTTON is pressed and no scan data is entering VTube-LASER. There are two conditions that will trigger the LASER SCAN FILTER sound:
|
NEW - PRESS ACCEPT BUTTON WITHOUT AIMING AT THE PART
VTube-LASER operators know that previous versions of VTube-LASER require that you aim the LASER scanner at the part when you press the accept button at the end of a scan.
We have redesigned the scanning engine so it no longer requires this in-range scanning position. |
NEW - HERBER Bender Corrections Through a Network (VTube-LASER Only)
NEW - HERBER Bender Setup From Solid Model Through a Network (VTube-LASER or VTube-STEP)
NEW - VTUBE-LASER TUNED TO WORK WITH THE NEW FARO 6.1.2.7 USB DRIVER
FARO USB driver 6.1.2.7 is a rewrite of the USB driver. It has many improvements that are very much worthwhile - like the scanner calibration is much improved.
|
OTHER CHANGES
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature