Difference between revisions of "VTube-LASER v2.9.17"
(→25pxNEW - MAX Points for Cylinder Stripes Is Now 50) |
(→25pxNEW - MAX Points for Cylinder Stripes Is Now 50) |
||
Line 88: | Line 88: | ||
<td> | <td> | ||
[[image:vtl_v2.9.17_Max50PointsPerStripeForCylinders.png|442px]] | [[image:vtl_v2.9.17_Max50PointsPerStripeForCylinders.png|442px]] | ||
+ | </td> | ||
+ | |||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]]FIX - Split Bend Corrections in Bend Setup == | ||
+ | |||
+ | <table cellpadding=10 width=1200> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=300> | ||
+ | A customer discovered that the Split Bend corrections (for a 180-degree bend) were being applied in Bender Setup as two adjacent 90-degree bends. So the 180-degree bend was receiving half the correction.<br><br> | ||
+ | This is because VTube-LASER was not compressing the data properly when Split Bend measure was on. <br><br> | ||
+ | This has been fixed in this version. | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | [[image:vtl_v2.9.17_180degreeSplitBend_BenderSetupCorrectionFix.png|442px]] | ||
</td> | </td> | ||
Revision as of 03:57, 28 November 2018
Revision 2.9.17Release Date: Unreleased
|
Contents |
NEW - Scan and Measure Point Clouds
VTube-LASER now handles point clouds in storage we call "buckets." This allows you to scan anything into VTube-LASER - not just tubes. With this feature:
|
NEW - Automatic Reset Straight Count at Measure
If VTube-LASER starts a measure setup with ZERO straights, then it automatically resets to the MASTER straight count. |
NEW - MAX Points for Cylinder Stripes Is Now 50
Through some experimentation, any point count above 50 per stripe is not helpful in VTube-LASER. For example, as you approach 1000 points per stripe, it slows the math engine significantly and actually causes more Cylinder Fit problems than it solves. |
FIX - Split Bend Corrections in Bend Setup
A customer discovered that the Split Bend corrections (for a 180-degree bend) were being applied in Bender Setup as two adjacent 90-degree bends. So the 180-degree bend was receiving half the correction. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature