Difference between revisions of "VTube-LASER v2.9.17"

From ATTWiki
Jump to: navigation, search
(25pxNEW - Scan Point Clouds into SOLIDWORKS)
(Send to SOLIDWORKS)
Line 164: Line 164:
 
<td width=300>
 
<td width=300>
 
===Send to SOLIDWORKS===
 
===Send to SOLIDWORKS===
Then we press one button to transfer the point cloud to SOLIDWORKS<br><br>
+
Press one button to transfer the scanned point cloud to SOLIDWORKS. The transfer takes about 5 seconds.<br><br>
  
 
</td>
 
</td>

Revision as of 21:11, 21 December 2018

Vtube-laser logo 1.96.png


Revision 2.9.17

Release Date: Unreleased
Current Build: 8


Vtube-laser v2.7 screenshot.png

Contents



Check.jpgNEW - Measure Guide Window

The new Measure Guide window draws a small model of the part with the current section highlighted with a color band.

This will help you visually identify which part of the tube to measure next.

This feature has an on/off switch in Measure Setup / Other. Also, you can view the window at any time from inside Measure Process Measure a tube.

Vtl v2.9.17 MeasureGuideWindow.png

MultiScan Mode

The feature works for either UniScan and MultiScan. For UniScan, the entire straight is banded. For MultiScan, the tangents of the straights are banded.

Vtl v2.9.17 MeasureGuideWindow MultiScan.png

Resizable

The window is resizable.

VTube-LASER will always remember the last position and size for this window. (This setting is remembered globally across all projects.)

Vtl v2.9.17 MeasureGuideWindow Resize.png

Multi-monitor Support

It can be moved to other monitors.

VTube-LASER will always remember the last monitor this window displays on. (This setting is remembered globally across all projects.)

Vtl v2.9.17 MeasureGuideWindow MonitorTracking.png

Setup

Setup the window in the Measure Process / Measure Tube option.

Vtl v2.9.17 MeasureGuideWindow Setup.png




Check.jpgNEW - Scan Point Clouds into SOLIDWORKS

VTube-LASER now handles point clouds in storage we call "buckets." This allows you to scan anything into VTube-LASER - not just tubes.

With this feature:

  • Scan point clouds into list of point cloud buckets using the LASER scanner.
  • Turn buckets of points on our off.
  • Select points on the screen then press DELETE to delete them from the buckets.
  • Measure the distance between any two points.
  • Transfer the point clouds into SOLIDWORKS.
  • Transfer the point clouds into an ASCII file for use in any other program.
  • Point clouds are stored and recalled to/from the VTube-LASER project file.
  • Point cloud changes are stored in the UNDO memory. If you delete the wrong set of points - just press UNDO.
  • Set the color of each bucket of point clouds.


Vtl v2.9.17 PointCloudDimension.png

Scanning Test: Malibu Control Arm

This is a Malibu Control Arm that we scanned in VTube-LASER.

The scan has a total of 19259 points in eight different buckets. Each bucket can be turned off and on.

Vtl v2.9.17 MalibuControlArm.png

Send to SOLIDWORKS

Press one button to transfer the scanned point cloud to SOLIDWORKS. The transfer takes about 5 seconds.

Vtl v2.9.17 MalibuControlArm SWpointcloud.png



Check.jpgNEW - VTube-LASER Now Automatically Resets Straight Count at Measure

VTube-LASER users are used to editing from a "0" for starting straight count to some positive value.

You won't have to do that any more in this new version - because now VTube will just fill in the correct straight count for you.

You can still change it manually at any time.

Vtl v2.9.17 SetupMeasureResetStraightCount.png



Check.jpgNEW - Store Cylinder Fit Tolerances for Reuse in Other Projects

The new Cylinder Fit Tolerances Named Setup feature allows you to store cylinder fit tolerances in Measure 1 for measuring cylinders for use in other projects. Each setup is stored in a list of named setups that can be used in any other project.

For example you could store a unique setup for measuring tubes with armor (like on brake lines) and another default one for regular tubes.

Vtl v2.9.17 Measure1NamedSetups Close.png

Vtl v2.9.17 Measure1NamedSetups.png



Check.jpgNEW - MAX Points for Cylinder Stripes Is Now 50

Through some experimentation, any point count above 50 per stripe is not helpful in VTube-LASER. For example, as you approach 1000 points per stripe, it slows the math engine significantly and actually causes more Cylinder Fit problems than it solves.

VTube-LASER will now allow up to 50 points per stripe for measuring cylinders - never more.

Vtl v2.9.17 Max50PointsPerStripeForCylinders.png



Check.jpgFIX - 180-degree Bend Correction Feature

This is important to you if you correct benders with 180-degree bends using Bender Setup communications.

The Split Bend corrections (for a 180-degree bend) were being applied in Bender Setup in the uncompressed mode - which means that only half the correction was being applied to 180-degree bends.

Also, the wrong number of rows was sent to Bender Setup - which meant that correction data was not properly aligned with the data at the bender. For example, for a single 180-degree bend part, there should only be two correction rows. However, VTube was sending three rows of data for two 90-degree bends.

This has been fixed in this version.

See the resulting correction data grid in the Bender Setup screen below the image.

Vtl v2.9.17 180degreeSplitBend BenderSetupCorrectionFix.png



Check.jpgNEW- Auto Disconnect When the FARO Driver is Busy

When the FARO driver is busy with other connections (like to CAM2), VTube-LASER would give an error then shutdown.

Now VTube-LASER closes the connection to the FARO arm and displays a message with a sound to let you know that the connection is closed.

Vtl v2.9.17 FAROAutoCloseConnectionWhenBusy.png




Check.jpgNEW- Auto Display of DRO (Digital Readout) When Moving from VTube-STEP to VTube-LASER

When the arm is connected to VTube, and the user changes from VTube-STEP to VTube-LASER, VTube now automatically displays the DRO window (Digital Readout).

Vtl v2.9.17 DRO.png



Check.jpgOther Changes

  • For HTML reports, the screen-image bmp file is now only copied to the html export folder when it is present in the html report.
  • In VTube-STEP, the export html report feature would display an error and would not save he html reports. This has been fixed.