Difference between revisions of "VTube-LASER v2.9.18"
(→25pxNEW - AUTOMATIC LASER SEPARATION Method for UniScan Mode) |
(→25pxNEW - Bender Setup Window CORRECTION DATA MAPPING Adds Flexibility to Corrections) |
||
Line 47: | Line 47: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]]NEW - Bender Setup Window CORRECTION DATA MAPPING Adds Flexibility to Corrections == | + | ==[[image:Check.jpg|25px]]NEW - Bender Setup Window CORRECTION DATA MAPPING Adds Extreme Flexibility to Corrections == |
<table cellpadding=10 width=1200> | <table cellpadding=10 width=1200> | ||
Line 53: | Line 53: | ||
<td width=300> | <td width=300> | ||
+ | If you have to skip rows for avoidance moves, then this feature is important for you.<br><br> | ||
Use correction mapping in Bender Setup to move corrections up or down columns and to ignore specific corrections.<br><br> | Use correction mapping in Bender Setup to move corrections up or down columns and to ignore specific corrections.<br><br> | ||
This ability is important for certain styles of benders - like SOCO, COMCO, and BendPro - because some users prefer to not use the teach mode to create avoidance moves. This ability allows the corrections to skip data that is used for extra moves or avoidance moves.<br><br> | This ability is important for certain styles of benders - like SOCO, COMCO, and BendPro - because some users prefer to not use the teach mode to create avoidance moves. This ability allows the corrections to skip data that is used for extra moves or avoidance moves.<br><br> | ||
Line 77: | Line 78: | ||
<br><br> | <br><br> | ||
− | |||
==[[image:Check.jpg|25px]]NEW - Move Bend Setup BLUE COLUMN Data Up or Down == | ==[[image:Check.jpg|25px]]NEW - Move Bend Setup BLUE COLUMN Data Up or Down == |
Revision as of 01:16, 9 March 2019
Revision 2.9.18Release Date: March 8, 2019
|
NEW - AUTOMATIC LASER SEPARATION Method for UniScan Mode
The NEW AUTOMATIC LASER SEPARATION method allows VTube-LASER to automatically control the UniScan separation distance between laser stripes based on the known MASTER tube length. See the VTube-LASER UniScan Automatic Laser Separation Tutorial for more information. |
NEW - Bender Setup Window CORRECTION DATA MAPPING Adds Extreme Flexibility to Corrections
If you have to skip rows for avoidance moves, then this feature is important for you.
|
NEW - Move Bend Setup BLUE COLUMN Data Up or Down
Use this feature combined with Correction Data Mapptin to skip rows for avoidance moves.
|
NEW - BLM CMM Communications Protocol
This protocol allows you to correct BLM benders using the BLM CMM protocol. This is now the recommended protocol for use with BLM benders. |
NEW - COMCO CSV Communications Protocol
This protocol allows you to correct COMCO benders through the CSV file import and export. |
NEW - OMCG SVNET Communications Protocol
This protocol allows you to correct OMCG benders. |
NEW - Now VTube has THREE Default Radii
Radius 1, Radius 2, and Radius 3 are now available in Part Setup. |
FIX - The Taskbar Icon Now Displays
VTube-LASER users discovered that the taskbar icon did not always display. This has been fixed. |
Other Pages
- See VTube-LASER Addata ZModem Communications Protocol for more information.
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature