(25pxMAJOR IMPROVEMENT FOR UNISCAN- AUTOMATIC LASER SEPARATION for UniScan Mode Improves Laser Scanning Signifcantly)
(25pxMAJOR IMPROVEMENT FOR UNISCAN - AUTOMATIC LASER SEPARATION for UniScan Mode Improves Laser Scanning Signifcantly)
Line 30: Line 30:
  
 
<td width=300>
 
<td width=300>
The new Automatic Laser Separation method allows VTube-LASER to automatically control the UniScan separation distance between laser stripes based on the known individual tube lengths. The result is a much improved experience when UniScan scanning tubes with straight lengths that vary much.<br><br>
+
The new Automatic Laser Separation method allows VTube-LASER to automatically control the UniScan separation distance between laser stripes based on the known individual tube lengths in the MASTER data. The result is a much improved experience when UniScan scanning tubes with straight lengths that vary much.<br><br>
 
This allows VTube-LASER to automatically lay stripes closer on shorter straights to collect more data - while making VTube spread out stripes on longer sections.<br><br>
 
This allows VTube-LASER to automatically lay stripes closer on shorter straights to collect more data - while making VTube spread out stripes on longer sections.<br><br>
 
The result is a much higher degree of successful scanning when switching from long straights to short staights and back.<br><br>
 
The result is a much higher degree of successful scanning when switching from long straights to short staights and back.<br><br>

Revision as of 20:43, 12 March 2019

Vtube-laser logo 1.96.png


Revision 2.9.18

Release Date: March 12, 2019
Current Build: 18


Vtube-laser v2.7 screenshot.png

Contents


Check.jpgMAJOR IMPROVEMENT FOR UNISCAN - AUTOMATIC LASER SEPARATION for UniScan Mode Improves Laser Scanning Signifcantly

The new Automatic Laser Separation method allows VTube-LASER to automatically control the UniScan separation distance between laser stripes based on the known individual tube lengths in the MASTER data. The result is a much improved experience when UniScan scanning tubes with straight lengths that vary much.

This allows VTube-LASER to automatically lay stripes closer on shorter straights to collect more data - while making VTube spread out stripes on longer sections.

The result is a much higher degree of successful scanning when switching from long straights to short staights and back.

We are convinced that this method is so useful that it is now switched on by default in the Measure Setup Separation Distance menu. You will not even know it is active - but you will experience much better succes in measuring short straights than in previous versions.

See the VTube-LASER UniScan Automatic Laser Separation Tutorial for more information.

Vtl v2.9.18 AutomaticLaserSeparation.pngRa8 stripes.png

Vtl v2.9.18 AutomaticLaserSeparation Graphic.png



Check.jpgNEW - Bender Setup Window CORRECTION DATA MAPPING Adds Extreme Flexibility to Corrections

If you have to skip rows in bender setup data for avoidance moves, then this feature is important for you.

Use correction mapping in Bender Setup to move corrections up or down columns and to ignore specific corrections.

This ability is important for certain styles of benders - like SOCO, COMCO, and BendPro - because some users prefer to not use the teach mode to create avoidance moves. This ability allows the corrections to skip data that is used for extra moves or avoidance moves.

Each column of adjustments now has their own color-coded Map column.

  • Yellow indicates that the adjustments were pushed down one row from the cell and downward in the grid.
  • Red indicates that a correction is ignored.
  • Pink indicates the the corrections are pulled up one row from the bottom of the grid.
  • Green indicates that the correction is used.



The Correction Mapping values are stored in the project files and recalled automatically when the project is loaded.

Vtl v2.9.18 BenderSetup CorrectionMappingCloseUp.png

Vtl v2.9.18 BenderSetup CorrectionMapping.png



Check.jpgNEW - Move Bend Setup BLUE COLUMN Data Up or Down

Use this feature combined with Correction Data Mapptin to skip rows for avoidance moves.

Vtl v2.9.18 PushLengthDown.png



Check.jpgNEW - BLM CMM Communications Protocol

This protocol allows you to correct BLM benders using the BLM CMM protocol. This is now the recommended protocol for use with BLM benders.

Vts v2.9.18 BenderSetup BLMCMM.png



Check.jpgNEW - COMCO CSV Communications Protocol

This protocol allows you to correct COMCO benders through the CSV file import and export.

Vts v2.9.18 BenderSetup COMCOCSV.png




Check.jpgNEW - OMCG SVNET Communications Protocol

This protocol allows you to correct OMCG benders.

See VTube OMCG Bender Correction for details.

Vts v2.9.18 BenderSetup OMCGSVNET.png



Check.jpgNEW - Now VTube has THREE Default Radii

Radius 1, Radius 2, and Radius 3 are now available in Part Setup.

Vtl v2.9.18 DefaultRadius123.png



Check.jpgFIX - The Taskbar Icon Now Displays

VTube-LASER users discovered that the taskbar icon did not always display. This has been fixed.

Vtl v2.9.18 TaskbarIcon.png



Check.jpgOther Changes

  • NEW - A new button in Tube Data Storage allows you to copy only the MEASURED back into main memory.

  • NEW - Autobuild Parametrics now calculates the CUT LENGTH automatically.